Шасси Cisco ASR-9010-AC-V2

Производитель: Cisco

Артикул: ASR-9010-AC-V2

Срок поставки: по запросу

Цена по запросу

Уточните условия поставки у менеджера.

Описание

ASR 9010 AC Chassis with PEM Version 2 Сервисный контракт Cisco SMARTnet (8x5xNBD) для данного устройства: CON-SNT-ASR901A

SpecificationCisco ASR 9010
Physical specificationsHeight: 36.75 in. (933.45 mm) (21 RU)Width: 17.38 in. (441.45 mm)Depth:? With doors: 29.03 in. (737.4 mm) ? Without doors: 28.24 in. (717.3 mm) Weight:? 155.6 lb (70.73 kg) (chassis with PEM) 231.6 lb (105.27 kg) (fully loaded, excluding linecards and power modules) – RSP, two v2 fan trays, PEMs
Slot orientationVertical
Cisco ASR 9000 Series RSPDual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards8 line-card slots
“Commons” components2 RSPs2 fan trays2 PEMs (either DC or AC)1 fan filter
Reliability and availabilityFabric redundancyFan redundancyFeed redundancyPower-supply redundancyRSP redundancySoftware redundancy
Rack mounting19-in. default21- and 23-in. adapters availableNote: Minimum 17.75-in. opening between posts is needed for proper operation
Cabinet mountingYesNote: Doors not recommended in enclosed cabinets
Wall mountingNo
AirflowFront-to-back
Performance
FabricOne per RSP:? Active/active nonblocking operation mode in dual-RSP redundant configuration? Fully redundant in dual-RSP redundant configuration? Built-in service-intelligence and traffic-prioritization capability
ThermalTwo fan trays:? 12 high-efficiency fans per tray? Variable-speed fans for optimal thermal performance? No single point of failure
Power
ModularityPay-as-you-grow power for future scalability, available in AC and DC.Multiple power module types:? 6 kW and 3 kW AC power modules? 4.4 kW and 2.1 kW DC power modulesNote: Mixing of AC and DC modules is not supported
Redundancy? AC: N+N redundancy? DC: N+1 redundancy? Power module redundancy? A/B Feed redundancy? PEM redundancy
Power zonesNo power zone restrictionsFully load-sharing power infrastructure
Power inputWorldwide ranging AC (200-240V, 50-60 Hz, 16A maximum)Worldwide ranging DC (-40 to -72V, 50A nominal, 60A maximum)
Power-module airflowFront-to-back
Environmental Specifications (All Entries Applicable to Cisco ASR 9006 and ASR 9010)
Operating temperature (nominal)41 to 104?F (5 to 40?C)
Operating temperature (short-term)ASR 9010: 23 to 122?F (-5 to 50?C)
Operating humidity (nominal) (relative humidity)5 to 90%
Storage temperature-40 to 158?F (-40 to 70?C)
Storage (relative humidity)5 to 93%
Operating altitude-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Regulatory Compliance (All Entries Applicable to Cisco ASR 9006 and ASR 9010)
Network Equipment Building Standards (NEBS)Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? SR-3580: NEBS Criteria Levels (Level 3)? GR-1089-CORE: NEBS EMC and Safety? GR-63-CORE: NEBS Physical Protection? VZ.TPR.9205: Verizon TEEER
ETSI StandardsCisco ASR 9006 and ASR 9010 Routers are designed to meet:? EN300 386: Telecommunications Network Equipment (EMC)? ETSI 300 019 Storage Class 1.1? ETSI 300 019 Transportation Class 2.3? ETSI 300 019 Stationary Use Class 3.1
EMC standards emissionCisco ASR 9006 and ASR 9010 Routers are designed to meet:? FCC Class 47CFR15 A? ICES 003 Class A? AS/NZS CISRP22 Class A? CISPR 22 (EN55022) Class A? VCCI Class A? BSMI Class A? IEC/EN 61000-3-12: Power Line Harmonics? IEC/EN 61000-3-11: Voltage Fluctuations and Flicker? EN55022: Information Technology Equipment (Emissions)? EN 50121-4: Railway EMC
EMC standards immunityCisco ASR 9006 and ASR 9010 Routers are designed to meet:? IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)? IEC/EN-61000-4-3: Radiated Immunity (10V/m)? IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)? IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)? IEC/EN-61000-4-5: Signal Surge Ports (1kV)? IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)? IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)? IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)? IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations? EN55024: Information Technology Equipment (Immunity)? EN50082-1/EN-61000-6-1: Generic Immunity Standard? EN 50121-4: Railway EMC
SafetyCisco ASR 9006 and ASR 9010 Routers are designed to meet:? UL/CSA/IEC/EN 60950-1? IEC/EN 60825 Laser Safety? ACA TS001? AS/NZS 60950? FDA Code of Federal Regulations Laser Safety
ПроизводительCisco

Характеристики

-40 to 158?F (-40 to 70?C)
Storage (relative humidity)
-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Regulatory Compliance (All Entries Applicable to Cisco ASR 9006 and ASR 9010)
41 to 104?F (5 to 40?C)
Operating temperature (short-term)
5 to 90%
Storage temperature
5 to 93%
Operating altitude
Airflow
Front-to-back
ASR 9010: 23 to 122?F (-5 to 50?C)
Operating humidity (nominal) (relative humidity)
Cabinet mounting
YesNote: Doors not recommended in enclosed cabinets
Cisco ASR 9000 Series line cards
8 line-card slots
Cisco ASR 9000 Series RSP
Dual redundant RSPs with integrated fabric in 2 slots
EMC standards emission
Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? FCC Class 47CFR15 A? ICES 003 Class A? AS/NZS CISRP22 Class A? CISPR 22 (EN55022) Class A? VCCI Class A? BSMI Class A? IEC/EN 61000-3-12: Power Line Harmonics? IEC/EN 61000-3-11: Voltage Fluctuations and Flicker? EN55022: Information Technology Equipment (Emissions)? EN 50121-4: Railway EMC
EMC standards immunity
Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)? IEC/EN-61000-4-3: Radiated Immunity (10V/m)? IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)? IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)? IEC/EN-61000-4-5: Signal Surge Ports (1kV)? IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)? IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)? IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)? IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations? EN55024: Information Technology Equipment (Immunity)? EN50082-1/EN-61000-6-1: Generic Immunity Standard? EN 50121-4: Railway EMC
Environmental Specifications (All Entries Applicable to Cisco ASR 9006 and ASR 9010)
Operating temperature (nominal)
ETSI standards
Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? EN300 386: Telecommunications Network Equipment (EMC)? ETSI 300 019 Storage Class 1.1? ETSI 300 019 Transportation Class 2.3? ETSI 300 019 Stationary Use Class 3.1
Modularity
Pay-as-you-grow power for future scalability, available in AC and DC.Multiple power module types:? 6 kW and 3 kW AC power modules? 4.4 kW and 2.1 kW DC power modulesNote: Mixing of AC and DC modules is not supported
Network Equipment Building Standards (NEBS)
Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? SR-3580: NEBS Criteria Levels (Level 3)? GR-1089-CORE: NEBS EMC and Safety? GR-63-CORE: NEBS Physical Protection? VZ.TPR.9205: Verizon TEEER
One per RSP:? Active/active nonblocking operation mode in dual-RSP redundant configuration? Fully redundant in dual-RSP redundant configuration? Built-in service-intelligence and traffic-prioritization capability
Thermal
Performance
Fabric
Physical specifications
Height: 36.75 in. (933.45 mm) (21 RU)Width: 17.38 in. (441.45 mm)Depth:? With doors: 29.03 in. (737.4 mm) ? Without doors: 28.24 in. (717.3 mm) Weight:? 155.6 lb (70.73 kg) (chassis with PEM) 231.6 lb (105.27 kg) (fully loaded, excluding linecards and power modules) – RSP, two v2 fan trays, PEMs
Power Input
Worldwide ranging AC (200-240V, 50-60 Hz, 16A maximum)Worldwide ranging DC (-40 to -72V, 50A nominal, 60A maximum)
Power zones
No power zone restrictionsFully load-sharing power infrastructure
Power-module airflow
Front-to-back
Rack mounting
19-in. default21- and 23-in. adapters availableNote: Minimum 17.75-in. opening between posts is needed for proper operation
Redundancy
? AC: N+N redundancy? DC: N+1 redundancy? Power module redundancy? A/B Feed redundancy? PEM redundancy
Reliability and availability
Fabric redundancyFan redundancyFeed redundancyPower-supply redundancyRSP redundancySoftware redundancy
Safety
Cisco ASR 9006 and ASR 9010 Routers are designed to meet:? UL/CSA/IEC/EN 60950-1? IEC/EN 60825 Laser Safety? ACA TS001? AS/NZS 60950? FDA Code of Federal Regulations Laser Safety
Slot orientation
Vertical
Specification
Cisco ASR 9010
Two fan trays:? 12 high-efficiency fans per tray? Variable-speed fans for optimal thermal performance? No single point of failure
Power
Wall mounting
No
Производитель
Cisco
“Commons” components
2 RSPs2 fan trays2 PEMs (either DC or AC)1 fan filter

Спецификации

Подробную спецификацию предоставим по запросу. Укажите необходимые интерфейсы, производительность и условия эксплуатации.

Загрузки

Документы для скачивания пока не добавлены. Запросите инструкцию или технический паспорт у менеджера.

Отзывы (0)

Отзывов об этом товаре пока нет.

Поделитесь опытом использования

Отзыв появится после проверки. Email нужен для связи с вами и не публикуется.

Как уточнить цену и заказать

Как получить актуальную цену?

Нажмите «Запросить КП» в карточке товара, укажите количество и контактные данные. Название и артикул товара попадут в заявку автоматически. Актуальную стоимость и условия поставки менеджер укажет в коммерческом предложении. Цены на сайте носят информационный характер и не являются публичной офертой.

Как узнать наличие, комплектацию и срок поставки?

Укажите нужную модель, количество и город доставки в комментарии к запросу КП. Менеджер уточнит наличие, комплектацию и условия поставки для вашего запроса.

Можно ли подобрать оборудование под задачу?

Опишите конфигурацию сети, требуемую производительность и интерфейсы в форме запроса. Поможем сравнить модели и подобрать совместимые аксессуары. Контакты отдела продаж · Доставка и оплата.

Коммерческое предложение

Запросить КП

Информация для покупателей

Об актуальности цен

Цены на сайте носят информационный характер и не являются публичной офертой. Актуальная стоимость и условия поставки будут указаны в коммерческом предложении после отправки запроса.